Relays, circuit boards and brushes

When a unit will not start or will not stop, the relay or board is the usual suspect after the inlet contacts and hose switch.

CentralVacuums.co is reader-supported. When you buy through links on our site, we may earn a commission at no extra cost to you. How we make money →

Relays, transformers and circuit boards

What It Is

The switching electronics in the power unit. Older units use a separate step-down transformer (120/240 V to ~24 V) plus a relay whose 24 V coil closes heavy contacts carrying motor current (MD sells a 28 A relay that 'replaces all relays in 110-240 V systems' and must be mounted upright). Modern units combine transformer, relay and often a mini-breaker on a single circuit board rated by voltage, amperage and motor count (MD boards: single-motor 15 A/18 A 120 V, dual-motor 15 A/28 A 120 V, 7 A/12 A/18 A 240 V; Alutron A517-02 'Control Board 100550' 15 A 250 V for Beam/Eureka/Electrolux/Honeywell). 'Universal relay control boxes' are stand-alone relay+transformer enclosures that let a unit with a dead board, or a shop-built unit, be controlled by standard low-voltage inlets.

What It Does

Takes the low-voltage signal from the inlet contacts and switches line voltage to the motor(s). Boards may add soft-start, run-on delay, dual-motor staging and a thermal mini-breaker.

What Fails

  • Relay contacts wear/pit (unit will not start or chatters); relay sticks closed (unit runs continuously even with the low-voltage wires removed).
  • Transformer open winding (no 24 V, no click).
  • Mini breaker (10/15/20 A) burns out after repeated motor overheating.
  • Cracked solder joints or burnt traces on the board.

How To Test

  • Unplug the unit. Disconnect the low-voltage pair at the unit, plug back in: if it still runs, the relay/board is stuck - replace. If it stops, the short is in the wire or an inlet (coin/screw bridging contacts).
  • Unit will not start: use the manual switch. A click with no motor = relay is being energized, motor is dead. No click = check cord, then transformer/relay.
  • Transformer: with 120 V on the primary, briefly touch the two low-voltage leads together; a small spark means the transformer is good (MD).
  • Relay: applying 24 V to the coil terminals should produce a click; polarity does not matter.
  • Board bench test (MD): wire neutral to NTL, line to 'power in', plug in, short the low-voltage terminals with a jumper. Spark + click = transformer and relay work. No spark = transformer bad. No spark, no click = relay bad, replace board. Spark + click but no motor = plug a 110 V lamp across 'Motor Neutral' and 'Motor Power'; if it does not light, the relay contacts are bad.
  • Choose a replacement board by voltage (120/240), single vs dual motor and motor amps (board rating must exceed motor draw); MD warns that some listed titles and descriptions disagree on amperage, so confirm before ordering.

Compatibility Checks

  • Match board to the number of motors and total amperage.
  • Separate relays need a transformer sized for them (MD 28 A relay requires the large transformer).
  • A universal relay box works with any 2-wire low-voltage inlet system and any 120 V single-motor unit within its amp rating.

Common Mistakes

  • Replacing the motor when only the relay/board failed (or vice versa) - test the relay click first.
  • Ignoring a continuously running unit (burns the motor and bag/filter).
  • Using a 15 A board on a motor that draws more than 15 A.

When To Replace

When the tests above show no click, no spark, or no output; when a mini-breaker trips repeatedly even after brush replacement; or when visible burn marks appear. Boards are often cheaper than a transformer+relay pair.

Sources: builtinvacuum.com, builtinvacuum.com, builtinvacuum.com, builtinvacuum.com, builtinvacuum.com, vacuflo.com

Relays, circuit boards and brushes: what's available

3 products · 0 with manufacturer-confirmed specs

Ordered by how well we could verify each one. "Manufacturer" means specs came from the maker's own sheet or manual; "listing" means we only have the retailer's description, so check the part number against yours before you buy.

electrical

Carbon Brush 4-Pack for Ametek Lamb 2311480 / 333261

Universal / generic

Match to the Lamb motor number on the motor label; compare shape/dimensions and lead/terminal style before installing; some require soldering the lead.

electrical

Johnny Vac Single Motor Circuit Board 15 A 120 V

Johnny Vac

Any single-motor 120 V unit drawing under 15 A; same class as the MD 'Single Motor 15A 120V' board. Johnny Vac (Montreal) also lists SWC18 18 A dual-motor and SWC901 2024 boards.

electrical

Imperium Universal Central Vacuum Relay Control Box

Imperium

Lets any 120 V unit (or a unit with a failed board) be controlled by standard low-voltage inlets. Must exceed motor amperage.